We supply water-cooled ,air-cooled industrial chiller and please contact us for more details and quotation.
Water-cooled Industrial Chiller Technical Specifications:
| Model | Cooling capacity | Compressor Output Power (HP) | Refrigerant | Evaporator | Water-cooled Type Inlet&Outlet Pipe Dia | Blower`s Power (KW) | Water tank capa (L) | Pump Power (KW) | |
| KW | Kcal/hr | ||||||||
| RCM-3W RCM-3A |
7.5 | 6500 | 3 | R22 | Tube-in -shell |
1" | 0.25 | 50 | 0.75 |
| RCM-4W RCM-4A |
10 | 9000 | 4 | ||||||
| RCM-5W RCM-5A |
13.5 | 11500 | 5 | 1 1/2" | |||||
| RCM-8W RCM-8A |
20 | 16500 | 8 | 0.3 | 100 | 1.1 | |||
| RCM-10W RCM-10A |
25.5 | 22000 | 10 | 2" | 0.18×2 | ||||
| RCM-12.5W RCM-12.5A |
31.5 | 27000 | 12.5 | 0.3×2 | 150 | 2.2 | |||
| RCM-15W RCM-15A |
38.5 | 33000 | 15 | 2 1/2" | |||||
| RCM-20W RCM-20A |
50 | 44000 | 20 | 0.55×2 | 180 | 2.2 | |||
| RCM-25W RCM-25A |
62.5 | 54000 | 25 | 3" | 0.65×2 | 200 | |||
| RCM-30W RCM-30A |
77.5 | 66500 | 30 | 0.75×2 | 280 | ||||
| Model | Pump Max.Flow Rate (L/min) |
Pump Max. Pressure (kg/cm2) |
Outlet tube Size (Inch) |
Inlet Tube Size | Dain Outlet Size | Overflowing Opening | External Size for W Type (mm)W×L×H |
External Size for A Type (mm)W×L×H |
Gross Weight (kg) |
| RCM-3W RCM-3A |
80 | 2.0 | 1/2"×4(1"×1) Air-cooled type |
1/2"×4(1"×1) Air-cooled type |
1/2" | 1/2" | 580×1100×960 | 750×1440×1350 | 120 |
| RCM-4W RCM-4A |
140 | ||||||||
| RCM-5W RCM-5A |
180 | ||||||||
| RCM-8W RCM-8A |
150 | 1 1/2" | 1 1/2" | 800×1280×1050 | 800×1600×1500 | 220 | |||
| RCM-10W RCM-10A |
280 | ||||||||
| RCM-12.5W RCM-12.5A |
250 | 2" | 2" | 850×1450×1250 | 900×1700×1700 | 350 | |||
| RCM-15W RCM-15A |
400 | ||||||||
| RCM-20W RCM-20A |
400 | 2 1/2" | 2 1/2" | 1000×2000×1400 | 1000×2500×2000 | 450 | |||
| RCM-25W RCM-25A |
550 | ||||||||
| RCM-30W RCM-30A |
2 1/2" | 2 1/2" | 600 |
Please excuse for not note if some specification of products are changed.
Note:
1)The cooling capactity is measured when the outgoing ware temperature is 12℃ and ambient temperature is 30℃ .
2) The regrigerant can use R407.For coding,use "N".For example,RCM-10W-N.
3)The stardard voltage is 3∮,220V/380V,50/60Hz. We also can make it as your requirments.
Gold Member of SooCuu
, Main Products: Plastic Granulator, Plastic Crusher,Central Granulator, Hopper Dryer, Air-cooled industrial chiller, Water-cooled industrial chiller, Mixing machinery, Auto-loader, granulator, Cabinet Dryer, Dehumidifying,Drying,die casting, pneumatic cylinder, water filters, Plastic Shredder, Granulator and Recycling, links